67

8

Adapting the application individually

8.3

Implementing more additional functions in the signal flow

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameter

Parameter

Name

Info/Lenze setting

Moto

r potentiom

eter

C00806

Use of motor potentiometer

0 The motor potentiometer is not used.

• The analog value applied to the nIn_a

input is looped through without any

changes to the nOut_a output.

1 The motor potentiometer is used.

• The analog value applied at the nIn_a

input is led via the motor

potentiometer and provided at the

nOut_a output.

C00800

L_MPot_1: Upper limit

100.00 %

C00801

L_MPot_1: Lower limit

-100.00 %

C00802

L_MPot_1: Acceleration time

10.0 s

C00803

L_MPot_1: Deceleration time

10.0 s

C00804

L_MPot_1: Inactive fct.

Behaviour of the motor potentiometer function when

being deactivated via the bInAct input:

0 Keep output value
1 Deceleration via ramp to 0
2 Deceleration via ramp to the lower limit

(C00801)

3 Step change to 0
4 Jump to lower limit (C00800)
5 Acceleration via ramp to upper limit

(C00800)

C00805

L_MPot_1: Init fct.

Behaviour of the motor potentiometer function when

the device is switched on:

0 Load last value
1 Load lower limit
2 Load 0

Advertising