Motor does not rotate

Motor rotates irregularly

Cause

Remedy

DC-bus voltage is too low

• Red LED is blinking every 1 s

• Display in the keypad: LU

Check mains voltage

Controller is inhibited

• Green LED is blinking

• Display in the keypad:

Deactivate controller inhibit

• Note: Controller inhibit can be set via several

sources !

• C00158 displays all active sources for controller

inhibit.

Automatic start is inhibited

(Bit 0 in C00142 = 1)

LOW/HIGH edge at RFR

If required, correct starting condition with C00142

DC-injection braking (DCB) is active

Deactivate DC injection brake

Mechanical motor brake is not released

Release mechanical motor brake manually or electrically

Quick stop (QSP) is active

• Display in the keypad:

Deactivate quick stop

• Note: Quick stop can be set via several sources!

• C00159 displays all active sources of quick stop.

Setpoint = 0

Select setpoint

JOG frequency = 0 at activated JOG setpoint

Set JOG setpoint in C00039/1...15

Trouble is active

Clear fault

Assignment of several mutually exclusive functions with

a signal source in C00701

Correct configuration in C00701

Cause

Remedy

Motor cable is defective

Check motor cable

Maximum motor current in motor or generator mode is

set too low

Adjust settings to the application:

C00022: Imax in motor mode

C00023: Imax in generator mode

Motor is underexcited or overexcited

Check parameterisation:

C00006: Motor control

C00015: VFC: V/f base frequency

C00016: VFC: Vmin boost

Rated motor data (stator resistance, speed, current,

frequency, voltage) and cos ϕ and/or magnetising

inductance is not adapted to the motor data

Execute automatic motor parameter identification with

the C00002/23 device command

- or -

Adjust motor parameters manually:

C00084: Motor stator resistance

C00087: Rated motor speed

C00088: Rated motor current

C00089: Rated motor frequency

C00090: Rated motor voltage

C00091: Motor cosine phi

C00092: Motor magnetising inductance

Motor windings are wired incorrectly

Reverse from star connection to delta connection

Advertising