Diagnostics & troubleshooting

7.1

LED status displays for device status

44

Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7

Diagnostics & troubleshooting

7.1

LED status displays for device status

The control of the two LEDs "DRV-RDY" and "DRV-ERR" in the lower part on

the front of the inverter depends on the device status.
The meaning can be seen from the table below:

DRV-RDY DRV-ERR Description

Device status

(Display in C00137)

OFF

OFF

OFF or initialisation active

Init

OFF

Safe torque off is active

SafeTorqueOff

OFF

Device is ready to start

ReadyToSwitchOn

OFF

Device is switched on

SwitchedOn

OFF

Motor data identification/operation

OperationEnabled

The controller is ready to switch on, switched on or the operation is

enabled and a warning is indicated.

Fault active, quick stop

TroubleQSP

OFF

Trouble is active

Trouble

OFF

Fault is active

Fault

OFF

System fault is active

SystemFault

Legend

The symbols used for indicating the LED states have the following meaning:

LED is flashing once approx. every 3 seconds (slow flash)

LED is flashing once approx. every 1.25 seconds (flash)

LED is flashing twice approx. every 1.25 seconds (double flash)

LED is blinking every second

LED is permanently on