Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05

15

5

Before commissioning

5.2

General notes on parameters

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Menu structure
In the keypad, the parameters are classified into various menus and submenus.

• The USER menu includes a selection of frequently used parameters.

( 20)

• The Code list contains all parameters.
• The Go to param function enables you to reach the corresponding parameter directly.
• The Logbook logs all errors and their chronological history.
• The Diagnostics menu contains diagnostic/display parameters for displaying device-internal

process factors, current actual values and status messages.

LCD display
Headline
In the menu level: Menu name

In the parameter level: Parameter name
Three-part display
In the menu level: List of available menus

In the parameter level: Code/subcode and setting or actual value
Device status

Controller is switched on

Pulse inhibit is active

Controller is enabled

System fault is active

Controller is inhibited

"Fault" device status is active

Quick stop is active

Device status "Trouble" active

Current limit exceeded

Device status "TroubleQSP" active

Speed controller 1 in the limitation

A warning is indicated

Function - left function key

Function - right function key

Change parameter setting

(change to editing mode)

Accept change in the controller

(no saving with mains failure protection 

)

Back to main menu

Abort (discard change)

Parameter can only be changed when the controller is inhibited.

Save all parameter settings in the memory module safe against mains failure

Control elements

Execute the function assigned to the function key (see LCD display)

Execute the stop function set in C00469 (Lenze setting: Inhibit controller)

Deactivate stop function again (Lenze setting: Enable controller again)

In the menu level: Select menu/submenu

In the parameter level: Select parameter

In the editing mode: Change marked digits or select list entry

In the menu level: Select submenu/change to parameter level

In the editing mode: Cursor to the right

In the menu level: One menu level higher (if available)

In the parameter level: Back to menu level

In the editing mode: Cursor to the left