5before commissioning – Lenze E84AVSCx 8400 StateLine C User Manual

Page 20

Advertising
background image

5

Before commissioning

5.2

General notes on parameters

20

Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.4

User menu for quick access to frequently used parameters

When a system is installed, parameters must be changed time and again until the system runs

satisfactorily. The user menu of a device contains a selection of frequently used parameters to be

able to access and change these parameters quickly.

Tip!
The user menu can be freely configured in C00517.
In the »Engineer«, you can configure the user menu comfortably via the User menu tab (see

»Engineer« online help).
The password protection serves to restrict the access to the parameters of the user menu.

Then, all other parameters cannot be accessed without knowing the password and thus

protected against unwanted changes.

Parameter

Name

Lenze setting

User

m

enu

C00051

Display of actual speed value

-

C00053

Display of DC-bus voltage

-

C00054

Display of motor current

-

C00061

Display of heatsink temperature

-

C00137

Display of device status

-

C00166/3

Display of current error message

-

C00011

Reference speed

1500 rpm

C00039/1

Fixed setpoint 1

40.00 %

C00039/2

Fixed setpoint 2

60.00 %

C00012

Acceleration time - main setpoint

2.000 s

C00013

Deceleration time - main setpoint

2.000 s

C00015

V/f base frequency

50 Hz

C00016

Vmin boost

1.60 %

C00022

Imax in motor mode

depending on the device power

C00120

Setting of motor overload (I

2

xt)

100.00 %

C00087

Rated motor speed

1460 rpm

C00099

Display of firmware version

-

C00200

Display of firmware product type

-

C00105

Decel. time - quick stop

2.000 s

C00173

Mains voltage

0: "3ph 400V / 1ph 230V"

Highlighted in grey = display parameter