Adapting the application individually

8.1

Function block interconnection of the "Actuating drive speed" application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8

Adapting the application individually

This chapter describes further adaptation options of the application based on the respective

function block interconnection.

• Further functions that are first deactivated by default (e.g. ramp smoothing for the main speed

setpoint, speed limit values and speed blocking zones) can be activated in the main signal flow

through parameter setting.

• Moreover, the assignment of inputs and outputs can be reconfigured via configuration

parameters to e.g. use the process controller or the motor potentiometer sensibly.

8.1

Function block interconnection of the "Actuating drive speed" application

In case of the 8400 device version, every drive solution is realised as a "function block

interconnection" (abbr.: "FB interconnection"). Using this FB interconnection, any signal

interconnection can be implemented. Various function blocks are available for digital processing,

signal conversion and logic modules.
For special tasks it has proved of value to use the integrated technology applications as a basis for

modifications or extensions of the available FB interconnections.

I/O level & application level
The interconnection of the interfaces is shown in the I/O level of the function block editor according

to the selected control mode. In the "deeper" application level, the main signal flow is realised in the

form of an interconnection of various function and system blocks.
The following applies to the "StateLine C" version:

• The preconfigured signal links can be reconfigured in the I/O level if required.

Pre-assignment

of the input and output interfaces

( 63)

• Moreover, the applications integrated in the inverter can be reconfigured and extended by

individual functions.

From version 12.00.00 and »Engineer« V2.17

onwards, experienced users are offered the

opportunity to implement their own drive solutions independent of the predefined technology

applications by using so-called "free interconnections".