6commissioning – Lenze E84AVSCx 8400 StateLine C User Manual

Page 33

Advertising
background image

Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05

33

6

Commissioning

6.3

Adapting the most important parameters to the drive task

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.3

Adapting the most important parameters to the drive task

The following short overview contains the most important parameters for a quick commissioning.

• The following subchapters provide more detailed information on these parameters.
• A description of all parameters can be found in the reference manual of the controller and in the

Engineer online help.

Parameter

Name

Info/Lenze setting

Ba

sic sett

ings

C00011

Appl.: Reference speed

1500 rpm

C00059

Appl.: Reference frequency C11

-

C00015

VFC: V/f base frequency

50.0 Hz

VFC = Voltage Frequency Control

C00016

VFC: Vmin boost

1.60 %

C00022

Imax in motor mode

depending on the device power

C00120

Setting of motor overload (I²xt)

100.00 %

C00142

Auto-start option

0x19 ≡ Controller inhibit when

• the controller is switched on (device on)

• Undervoltage

• Loading of the Lenze setting

C00173

Mains voltage

0: "3ph 400V / 1ph 230V"

App

lic

at

io

n p

aram

ete

rs

C00034/1

AIN1: Configuration

0: "-10...+10 v"

AIN1 = analog input

C00026/1

AIN1: Offset

0.00 %

C00027/1

AIN1: Gain

1.0000

C00010/x

AIN1: Characteristic

see

parameter description

C00012

Acceleration time - main setpoint

2.000 s

C00013

Deceleration time - main setpoint

2.000 s

C00039/1

Fixed setpoint 1

40.00 %

C00039/2

Fixed setpoint 2

60.00 %

C00039/3

Fixed setpoint 3

80.00 %

C00105

Decel. time - quick stop

2.000 s

C00114

DIx: Polarity

No inversion

DIx = digital inputs

C00118

DOx: Polarity

No inversion

DOx = digital outputs

C00434/1

O1U: Gain

100.00 %

O1U = analog output

(voltage output)

C00435/1

O1U: Offset

0.00 %

Mo

tor

co

ntro

l

C00006

Motor control

6: "VFCplus:V /f linear"

C00018

Switching frequency

2: "8 kHz var./drive-opt."

C00021

Slip compensation

2.67 %

C00019

Auto-DCB: Threshold

3 rpm

DCB = DC-injection braking

C00036

DC braking: Current

50.00 %

C00106

Auto-DCB: Hold time

0.500 s

C00910/1

Max. pos. output frequency

1000 Hz

C00910/2

Max. neg. output frequency

1000 Hz

Highlighted in grey = display parameter