8

Adapting the application individually

8.2

Activating additional functions in the signal flow

60

Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.2.2

Speed blocking zones

If the speed setpoints in speed-variable drives are linearly increasing, for instance, the

frequency/speed range is divided into a number of equal time segments. Therefore, there may be

speeds during acceleration time which must be bridged very fast (e.g. natural resonant frequencies).
The skip frequency function offers the opportunity to select a range in which the initial speed is

maintained. If the speed setpoint leaves that range, the drive will be accelerated to reach the

desired speed.

Definition of the blocking zones
The subcodes of codes

C00632

and

C00633

can be used to define three zones which are to be

skipped by the output setpoint and which are to be passed as fast as possible by the ramp function

generator.

C00632/x

C00633/x

Note!

• Skip frequencies only affect main setpoints.
• It is not possible to exclude "0" speed if there is a sign reversal of the speed setpoint.

L_NSet_1: Max. skip freq.
Maximum limit values for the speed blocking zones

• Selection of the maximum limit values for the blocking zones in which the speed must not be constant.

Setting range

(min. value | unit | max. value)

0.00

%

199.99

Subcodes

Lenze setting

Info

C00632/1

0.00 %

L_NSet_1: Blocking speed 1 max

C00632/2

0.00 %

L_NSet_1: Blocking speed 2 max

C00632/3

0.00 %

L_NSet_1: Blocking speed 3 max

L_NSet_1: Min. skip freq.
Minimum limit values for the speed blocking zones

• Selection of the minimum limit values for the blocking zones in which the speed must not be constant.

Setting range

(min. value | unit | max. value)

0.00

%

199.99

Subcodes

Lenze setting

Info

C00633/1

0.00 %

L_NSet_1: Blocking speed 1 min

C00633/2

0.00 %

L_NSet_1: Blocking speed 2 min

C00633/3

0.00 %

L_NSet_1: Blocking speed 3 min