Quick commissioning with the keypad

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5. Optional settings

V/f base frequency: If the rated motor voltage differs from the mains voltage, the V/f base

frequency has to be adapted.

Reference speed: Depending on the setting of the V/f base frequency, it may be required to

adapt the setting of the reference speed in C00011 to go through the entire speed range of the

motor. (for general procedure see above.)

Vmin boost: The Vmin boost of the motor voltage serves to select a load-independent

magnetising current which is required for asynchronous motors. The torque behaviour of the

motor can be optimised by adapting the setting in C00016. (for general procedure see above.)

Based on the restart of the controller after

loading the Lenze setting:

• Press the function key

to change to the main

menu.

• Go to the main menu and use the /

navigation keys to select the "Code list" entry.

• Change to this level by pressing the navigation

key .

• Navigate to the parameter C00015 by repeatingly

pressing the  navigation key.

• Then use the

function key to switch over to

the editing mode.

• Set the value according to the following formula

using the navigation keys:

V

frequency inverter

: Mains voltage 400 V or 230 V

U

ratedmot

: Rated motor voltage depending on the connection

method

f

rated

: Rated motor frequency

• Use the

function key to accept the changed

setting and to leave the editing mode.

Actual speed

C00051

0 rpm

CINH

Par1 8400 StateLine C

SAVE

Code list

Go To Param

USER - Menu

CINH

V/f base frequency

C00015

50.0 Hz

CINH

EDIT

Load Lenze setting

C00002/001

Off / Finished

CINH

EDIT

C00015 [Hz]

U

FI

[V]

U

Ratedmot

[V]

----------------------------------

f

Rated

[Hz]

=

V/f base frequency

C00015

CINH

ESC

0

050.0 Hz

OK