7.5

Error messages

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

ID1: Motor data identification error

During the identification of the motor

parameters, an error has occurred.

Possible causes:

• Interrupted motor cable.

• Switched-off power section during the

identification.

• Implausible start parameter settings.

• Check the motor connections and the

corresponding plug connector on the

device and, if necessary, the motor

terminal box.

• Correct start parameters for the motor

parameter identification (motor

nameplate data).

• Stable power supply of the device.

ID3: CINH motor data identification

The device has detected controller inhibit

during the motor data identification.

• This cancels the identification process.

The Lenze setting of the motor data is

used.

• Do not set controller inhibit during the

motor data identification.

• Do not execute any device function

which may activate controller inhibit.

ID4: Resistor identification error

The device has recognised that an error

has occurred in the calculation of the

motor cable resistance.

• The parameters for cable cross-section

and cable length are implausible.

Enter sensible values for cable cross-

section and motor cable length.

LP1: Motor phase failure

Motor phase failure - power section

• This error message is displayed if a

motor phase carries less current of one

half-wave than set in C00599.

• Check the motor connections and the

corresponding plug connector on the

device and, if necessary, the motor

terminal box.

• Check the trigger threshold (C00599).

LU: DC bus undervoltage

The device has detected a DC bus

undervoltage. The inverter control is

switched off because the drive properties

of the motor control cannot be provided

anymore due to the DC bus undervoltage.

• Depending on the configuration of the

auto-start lock function, C00142 serves

to set that, if this error has been

tripped, the controller only starts after

the controller inhibit is switched.

• Switch on mains supply or ensure

sufficient supply via DC bus.

• Adjust setting in C00142 if required.

MCI1: Module missing / incompatible

The optional communication module has

been removed or there is a connection

problem or incompatibility with the

standard device.

• Check connection between the

communication module and standard

device.

• Check if the module is plugged in

correctly.

• In case of an incompatibility, either the

module or the software of the standard

device is out of date. In this case, please

contact Lenze.

OC1: Power section - short circuit

The device has recognised a short circuit of

the motor phases. To protect the device

electronics, the inverter control is

switched off.

• Mostly, incorrectly executed motor

connections are the cause.

• If the device is inappropriately

dimensioned with regard to the motor

load and the current limitation in the

controller (Imax controller) is set

incorrectly, this error message may also

occur.

• Check motor connections and the

corresponding plug connector on the

device.

• Only use permissible combinations of

device power and motor power.

• Do not set the dynamics of the current

limitation controller too high.

Error message

Cause

Remedies