Commissioning

6.3

Adapting the most important parameters to the drive task

42

Lenze · 8400 StateLine · Operating instructions · from Firmware V06.00 · DMS 1.2 EN · 12/2012 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00018

C00021

C00019

C00036

C00106

Switching frequency
Selection of the pulse width modulated switching frequency transferred from the inverter to the motor

• Select between an ideal setting for the drive which provides smooth running, and an optimal setting with regard

to the inverter which keeps its losses to a minimum (min. Pv).

• Both possibilities offer fixed and variable switching frequencies.

• When a variable switching frequency is selected, the switching frequency may change as a function of the load

and rotational frequency.

Selection list

(Lenze setting printed in bold)

1 4 kHz var./drive-optimised

15 2 kHz constant/min. Pv

2 8 kHz var./drive-optimised

16 4 kHz constant/min. Pv

3 16 kHz var./drive-optimised

17 8 kHz constant/min. Pv

5 2 kHz constant/drive-optimised

18 16 kHz constant/min. Pv

6 4 kHz constant/drive-optimised

21 8 kHz var./drive-opt./4 kHz min

7 8 kHz constant/drive-optimised

22 16 kHz var./drive-opt./4 kHz min

8 16 kHz constant/drive-optimised

23 16 kHz var./drive-opt./8 kHz min

11 4 kHz var./min. Pv

31 8 kHz var./min. Pv/4 kHz min

12 8 kHz var./min. Pv

32 16 kHz var./min. Pv/4 kHz min

13 16 kHz var./min. Pv

33 16 kHz var./min. Pv/8 kHz min

Slip compensation
Slip compensation for V/f characteristic control and sensorless vector control

• A higher slip compensation results in a higher increase in frequency and voltage when the machine is under load.

• After the motor to be used has been selected from the »Engineer« motor catalogue, the suitable value can be

entered automatically. An automatic detection via the motor parameter identification is possible as well.

Setting range

(min. value | unit | max. value)

Lenze setting

-100.00

%

100.00 2.67 %

Auto-DCB: Threshold
Setpoint speed threshold for automatic DC injection braking

• For speed setpoints with values below the thresholds a DC current is injected or the motor is not supplied with

current, depending on the setting.

Setting range

(min. value | unit | max. value)

Lenze setting

0

rpm

60000 3 rpm

DC braking: Current
Current value in [%] for DC-injection braking

• 100 % ≡ Imax in motor mode (

C00022

)

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

200.00 50.00 %

Auto-DCB: Hold time
Hold time of the automatic DC injection brake

• The DC injection brake is applied for the time set here if the value falls below the speed setpoint set in

C00019

.

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

999.000 0.500 s