2 assignment of the interfaces, 1 931e servo inverter, 2 931k servo inverter – Lenze 931K User Manual

Page 14: Assignment of the interfaces, 931e servo inverter, 931k servo inverter, Electrical installation

Advertising
background image

Electrical installation

Assignment of the interfaces
931E servo inverter

4

l

14

KHB 13.0004−EN 2.1

4.2

Assignment of the interfaces

4.2.1

931E servo inverter

The controller is connected to the PROFIBUS via the 9−pin Sub−D socket X4.1/X4.2.

View

Pin

Designation

Explanation

1

6

5

9

1

2

3

RxD/TxD−P

Data line B (received/transmitted data plus)

4

RTS

Request to send
(received/transmitted data, no differential signal)

5

M5V2

Data reference potential (ground to 5V)

6

P5V2

5 V DC / 30 mA (bus termination)

7

8

RxD/TxD−N

Data line A (received/transmitted data minus)

9

4.2.2

931K servo inverter

The controller is connected to the PROFIBUS via the M12 connector X4.1/X4.2.

X4.1 / X4.2 PROFIBUS

Input contact pattern Pin

no.

Signal

Specification

1

n. c.

Not assigned

2

RxD/TxD−
N

Receive / Transmit data −N (A line)

3

DGND

Data Ground (reference potential to VP)

4

RxD/TxD−
P

Receive / Transmit data −plus (B line)

5

Shield

Shield

Output contact
pattern

Pin
no.

Signal

Specification

1

VP

Power supply plus (5V)

2

RxD/TxD−
N

Receive / Transmit data −N (A line)

3

DGND

Data Ground (reference potential to VP)

4

RxD/TxD−
P

Receive / Transmit data −plus (B line)

5

Shield

Shield

Advertising