background image

Parameter setting

Physical units

7

l

44

KHB 13.0004−EN 2.1

U

E

U

A

x

1

x

2

931e_415

Fig. 8

Gearbox factors

U

E

Input−end speed

U

A

Output−end speed

x

1

Position_units in degrees

x

2

Position_units in mm

Notes on settings

ƒ

From the set physical units conversion factors are automatically generated
internally. The conversion factors consist of a numerator and a denominator and
may not be longer than 32 bits.

ƒ

The value of the feed constant is ignored for the respective physical unit if the feed
constant has a translatory unit and a rotatory unit is selected for the physical
quantity.

ƒ

If the entries for the factors or physical units are incorrect, an overflow occurs and
the value is rejected.

ƒ

Examples for incorrect settings:

Incorrect setting

Effect

Position in [revolutions] and
feed constant in [mm/revolution]

The feed constant is ignored.

Position in [mm] and
feed constant without a unit

The feed constant is considered as a gearbox factor.

Position in [mm] and
feed constant in [

mm/revolution]

The feed constant is evaluated using the factor 1000.

ƒ

The error message 59 ("General arithmetic error") is generated
– if incorrect settings result in values which cannot be represented after internal

conversion,

– if transition states occur which cause the overflow of physical units.
Remedy:
– Check the settings of the physical units and correct them if necessary.
– Save the settings and carry out a reset. If the error message 59 is not generated

anymore, the physical units are valid.