6.7.6

Motor data

ƒ

Via PNU 1290.1 (iit Ratio Motor) you can read out the actual utilisation of the I

2

t

limitation in [‰].

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1160

Temperature

Reading of different
temperatures.

0 Power stage

temperature

{1 °C}

Ċ

INT16

RO

Ċ

Reading of the current power
stage temperature.

1 Motor temperature

{1 °C}

Ċ

INT16

RO

Ċ

Reading of the current motor
temperature.

1290

Motor Data

Overload protection for the
motor connected.

0 iit Time Motor

2000

0

{1 ms}

10000

Ċ

UNIT16

RW

Ċ

Time for which the motor is
fed with the specified
maximum current.

l

When the time has
elapsed, the motor current
is automatically limited to
the rated current set.

1 iit Ratio Motor

{1 ‰}

Ċ

UNIT16

RO

Ċ

Reading−out of the actual
utilisation of the I

2

t

limitation.

6.7.7

Operating modes

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1500

0 Operating Mode

Ċ

UINT8

RO

Ċ

00

h

Speed control

Reading−out of the operating
mode.

10

h

Positioning