Commissioning

"Positioning" mode

PNUs for parameter setting

6

l

39

KHB 13.0004−EN 2.1

Characteristics

Possible settings

Name

PNU

Description

Selection

Lenze

Name

PNU

1051

0 Home Offset

0

−32767

{1 inc}

32767

Ċ

INT32

RW

Ċ

Definition of the distance
between the zero position
and the reference point of a
homing sequence.

l

Positive values shift the
zero point to the positive
direction with respect to
the reference point.