Appendix, Table of parameter numbers (pnu) – Lenze 931K User Manual

Page 72

Advertising
background image

Appendix

Table of parameter numbers (PNU)

10

l

72

KHB 13.0004−EN 2.1

Characteristics

Possible settings

Name

PNU

Description

Selection

Lenze

Name

PNU

1290

Motor Data

Overload protection for the
motor connected.

0 iit Time Motor

2000

0

{1 ms}

10000

Ċ

UNIT16

RW

Ċ

Time for which the motor is
fed with the specified
maximum current.

l

When the time has
elapsed, the motor
current is automatically
limited to the rated
current set.

1 iit Ratio Motor

{1 ‰}

Ċ

UNIT16

RO

Ċ

Reading−out of the actual
utilisation of the I

2

t

limitation.

1350

0 Enable Logic

0

Ċ

UNIT16

RW

Ċ

Controller is enabled via:

Selection of the source for
controller enable

0

Digital input DIN 9

1

Digital input DIN 9 and RS232

3

Digital input DIN 9 and PROFIBUS

1500

0 Operating Mode

Ċ

UINT8

RO

Ċ

00

h

Speed control

Reading−out of the operating
mode.

10

h

Positioning

1601

Error Code

Error messages

0 Error Field 0

Ċ

UINT32

RO

Ċ

Error numbers 1 ... 32 of the
controller

1 Error Field 1

Ċ

UINT32

RO

Ċ

Error numbers 33 ... 64 of the
controller

1610

Error Management

Error management

0 Error Number

Ċ

UNIT8

RW

Ċ

1

h

{1}

40

h

Selection of the error number
for which a response is to be
set under PNU 1610.1.
Overview of error numbers:

^ 62

1 Error Reaction Code

Ċ

UNIT8

RW

Ċ

00

h

No response

Response of the controller to
an error event.
Notes on settings:

^ 62

03

h

Warning

05

h

Emergency stop

08

h

Power stage off (motor coasts to
standstill)