3 position data set at starting of positioning, 4 jerk limitation, Position data set at starting of positioning – Lenze 931K User Manual

Page 50: Jerk limitation, Parameter setting

Advertising
background image

Parameter setting

"Positioning" mode
Position data set at starting of positioning

7

l

50

KHB 13.0004−EN 2.1

7.4.3

Position data set at starting of positioning

ƒ

Selection of the position data set to be started via the control word 1 when a
command to start a positioning process is issued.

The controller is provided with 64 storable standard position data sets which can be
selected via 8 bits.

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1002

0 Start Set Number

68

Ċ

UINT8

RW

Ċ

0 ... 63

Standard position data sets

When positioning is started
via control word 1, the
selected data set is activated.

64 ... 67

Reserved

68

PROFIBUS position data set

7.4.4

Jerk limitation

ƒ

Activation of the jerk−limited ramp.

With the activation the maximum time (50 ms) is automatically set for the ramp. Only the
activation can be controlled via Profibus.

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1003

0 Motion Profile Type

0

Ċ

UNIT16

RW

Ċ

0

Jerk−limited ramp is deactivated

The acceleration/deceleration
time of the ramp cannot be
adjusted. When the ramp is
activated, the maximum time
(50 ms) is set automatically.

2

Jerk−limited ramp is activated

Advertising
This manual is related to the following products: