Appendix, Table of parameter numbers (pnu) – Lenze 931K User Manual

Page 70

Advertising
background image

Appendix

Table of parameter numbers (PNU)

10

l

70

KHB 13.0004−EN 2.1

Characteristics

Possible settings

Name

PNU

Description

Selection

Lenze

Name

PNU

1051

0 Home Offset

0

−32767

{1 inc}

32767

Ċ

INT32

RW

Ċ

Definition of the distance
between the zero position
and the reference point of a
homing sequence.

l

Positive values shift the
zero point to the positive
direction with respect to
the reference point.

1100

0 Position Actual

Value

{1 inc}

Ċ

INT32

RO

Ċ

Actual position value. The
value is scaled to the physical
unit set for PROFIBUS.

1101

0 Velocity Actual

Value

{1 rpm}

Ċ

INT32

RO

Ċ

Actual speed value. The value
is scaled to the physical unit
set for PROFIBUS.

1102

0 Current Actual

Value

{1 ‰}

Ċ

INT32

RO

Ċ

Actual value of active
current. The value refers to
the rated motor current.

1140

0 Digital Outputs

0

Ċ

UINT32

RW

Ċ

Bit

Value

Triggering of the digital
outputs.
Important! Up to 10 ms may
pass between triggering and
switching of the output.
The state of an output can be
checked by reading out the
parameter.

0

00000001

h

Holding brake
(read only)

1 ... 15

Reserved

16

00010000

h

Ready for
operation (read
only)

17, 18

00060000

h

DOUT1, DOUT2
(read and write)

19 ... 32

Reserved

1141

0 Digital Inputs

0

Ċ

UINT32

RO

Ċ

Bit

Value

Actual states of the digital
inputs.
The available digital inputs
depend on the
parameterisation of the
controller

0

00000001

h

Negative limit
switch (DIN7)

1

Reserved

2

00000002

h

Positive limit
switch (DIN7)

3

00000008

h

Controller enable
is missing (DIN9)

16 ... 25

03FF0000

h

DIN0 ... DIN9

26 ... 32

Reserved