Commissioning – Lenze 931K User Manual

Page 26

Advertising
background image

Commissioning

Settings on the controller (slave)
Definition of parameter numbers (PNU) in the telegram editor

6

l

26

KHB 13.0004−EN 2.1

931E_025

5. Select "Respond telegram" in the Telegram type field.

– Byte 0 (telegram identifier, not visible) and the entries for byte 1 (ADR − 1) and

byte 2 / byte 3 (ADR − 2) are necessary for faultless communication. Do not change
these entries.

6. Click on the Append entry button to enter a PNU.

– If you want to enter the PNU in hexadecimal notation, activate the hexadecimal

format in the Append entry box.

– If you want to change a PNU, select the PNU and click on the Change entry button.
– If you want to delete the PNU entered last, click on the Delete last entry button.

)

Note!

ƒ

If necessary, enter PNU 2010 as a wildcard to make the telegram length
match the parameterised telegram length of the master.

ƒ

Check that the parameterised telegram length corresponds to the memory
allocation (see arrows in the screenshot of the "Profibus telegram editor"
dialog box).