Appendix

Table of parameter numbers (PNU)

10

l

73

KHB 13.0004−EN 2.1

Characteristics

Possible settings

Name

PNU

Description

Selection

Lenze

Name

PNU

2000

0 PKW Access

0

Ċ

2 ×
UINT32

RW

Ċ

Byte

Value

Meaning

Manufacturer−specific access
to the parameter identifier
value (PKW).
In the receive and response
messages only one access is
possible. For this access the
corresponding PNU must be
entered under the same
address in all receive and
response messages used and
it must be parameterised
accordingly.

0

00

h

No access

41

h

Read access

42

h

Write access

(All other values are
reserved)

1, 2

Parameter number (PNU)

3

Subindex of PNU

4 ... 7

Data

2010

Placeholder

0 8 Bit

0

Ċ

UINT8

RW

Ċ

1 16 Bit

0

Ċ

UINT16

RW

Ċ

2 32 Bit

0

Ċ

UINT32

RW

Ċ

Wildcard to adapt the
telegram length of the slave
to the telegram length of the
master.

2011

0 Element 0

0

Ċ

UINT32

RW

Ċ

32−bit wildcard to adapt the
telegram length of the slave
to the telegram length of the
master.
The function is identical to
that of PNU 2010,
subindex 2.