Parameter setting

"Positioning" mode

Homing modes

7

l

51

KHB 13.0004−EN 2.1

7.4.5

Homing modes

ƒ

Selection of the homing method.

A detailed description of the different methods is given in the software manual for the
controller.

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1050

0 Homing Method

1

Ċ

INT8

RW

Ċ

Homing to

Selection of the homing
method to be used.

1

the negative limit switch with zero
pulse evaluation

2

the positive limit switch with zero
pulse evaluation

17

the negative limit switch

18

the positive limit switch

33, 34

the zero pulse

35

the actual position (no movement)

−1

the negative end stop with zero pulse
evaluation

−2

the positive end stop with zero pulse
evaluation

−17

the negative end stop

−18

the positive end stop