3 pnus for parameter setting, 6 "positioning" mode, Pnus for parameter setting – Lenze 931K User Manual

Page 30: Positioning" mode, Commissioning, Positioning" mode pnus for parameter setting

Advertising
background image

Commissioning

"Positioning" mode
PNUs for parameter setting

6

l

30

KHB 13.0004−EN 2.1

6.5.3

PNUs for parameter setting

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1010

0 Target Velocity

0

0

{1 rpm}

6000

Ċ

INT32

RW

Ċ

Selection of the speed
setpoint.

l

If the speed control mode
is selected in SDC, the
selector under "setpoint
selection" changes over if
required: AIN0/1, Profibus
or RS232

1011

Acceleration for
Velocity Control

Ċ

UINT32

RW

Ċ

Setting the acceleration and
deceleration for the speed
control mode

0 Acceleration

Velocity Control

10000

0

{1 rpm/s}

20000 Acceleration, the value set is

valid for both directions of
rotation

l

Reads out only the actual
value for the positive
direction of rotation

1 Deceleration

Velocity Control

10000

0

{1 rpm/s}

20000 Deceleration, the value set is

valid for both directions of
rotation

l

Reads out only the actual
value for the positive
direction of rotation

2 All Accelerations

Velocity Control

10000

0

{1 rpm/s}

20000 Acceleration and

deceleration, the value set is
valid for both directions of
rotation

l

Writes the value set to
PNU 1011, subindexes 0
and 1

l

Reads out the actual value
for the positive direction
of rotation under
PNU 1011, subindex 0

1101

0 Velocity Actual

Value

{1 rpm}

Ċ

INT32

RO

Ċ

Actual speed value. The value
is scaled to the physical unit
set for PROFIBUS.

1102

0 Current Actual

Value

{1 ‰}

Ċ

INT32

RO

Ċ

Actual value of active current.
The value refers to the rated
motor current.