Commissioning – Lenze 931K User Manual

Page 33

Advertising
background image

Commissioning

"Positioning" mode

Positioning

6

l

33

KHB 13.0004−EN 2.1

Adjustment

ƒ

Simple travel task
– Select position data set (0 … 63) under PNU 1002. (

35)

– Activation: Control word 1, set bit 6 from 0

® 1.

– The controller stops when the target position has been reached. Bit 10 of status

word 1 is used to signal the reaching of the target position to the master.

v

1

v

2

t

0

t

1

t

2

t

3

t

v

931e_407

Fig. 5

Simple travel task

ƒ

Sequence of travel tasks
– Select position data set (0 … 63) under PNU 1002. (

35)

– Activation: Control word 1, set bit 13 = 0.
– When a target position has been reached, the controller immediately starts to

approach the next target position.

v

1

v

2

t

0

t

1

t

2

t

3

t

v

931e_408

Fig. 6

Sequence of travel tasks

)

Note!

It is possible to interrupt the running travel task and immediately start the
next travel task:

ƒ

Select PROFIBUS position data set (68) under PNU 1002. (

36)

ƒ

Activation: Control word 1, set bit 13 = 1.
– Interruption of the positioning process. Start of next travel task.

Advertising