7 actual values, 1 actual position, 2 actual speed value – Lenze 931K User Manual

Page 40: 3 actual value of active current, Actual values, Actual position, Actual speed value, Actual value of active current, Commissioning

Advertising
background image

Commissioning

Actual values
Actual position

6

l

40

KHB 13.0004−EN 2.1

6.7

Actual values

6.7.1

Actual position

ƒ

Reading the actual position.

Due to the physical units, the resulting value may be higher than the maximum value
which can be represented by PNU 1100.

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1100

0 Position Actual

Value

{1 inc}

Ċ

INT32

RO

Ċ

Actual position value. The
value is scaled to the physical
unit set for PROFIBUS.

6.7.2

Actual speed value

ƒ

Reading the actual speed value.

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1101

0 Velocity Actual

Value

{1 rpm}

Ċ

INT32

RO

Ċ

Actual speed value. The value
is scaled to the physical unit
set for PROFIBUS.

6.7.3

Actual value of active current

ƒ

Reading the actual value of the active current.

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1102

0 Current Actual

Value

{1 ‰}

Ċ

INT32

RO

Ċ

Actual value of active current.
The value refers to the rated
motor current.

Advertising