6 pnus for parameter setting, Pnus for parameter setting, Commissioning – Lenze 931K User Manual

Page 38: Positioning" mode pnus for parameter setting

Advertising
background image

Commissioning

"Positioning" mode
PNUs for parameter setting

6

l

38

KHB 13.0004−EN 2.1

6.6.6

PNUs for parameter setting

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1000

0 Position Set

Number

68

Ċ

UINT16

RW

Ċ

0 ... 63

Standard position data sets

Position data sets of the
controller. The selected data
set can be parameterised via
PNU 1001.
For position data set 68,
additional settings can be
transferred via bits 4, 12 and
13 of control word 1.

64 ... 67

Reserved

68

PROFIBUS position data set

1001

Position Data

Ċ

INT32

RW

Ċ

Parameterisation of the
position data set selected via
PNU 1000.

0 Target Position

0

−32768

{1 inc}

32768 Target position

1 Profile Velocity

1000

0

{1 rpm}

3000 Travelling speed

3 Acceleration

Positioning

10000

0

{1 rpm/s}

20000 Acceleration

4 Deceleration

Positioning

10000

0

{1 rpm/s}

20000 Deceleration

5 All Accelerations

Positioning

10000

0

{1 rpm/s}

20000 Acceleration and deceleration

l

Writes the set value to
PNU 1001.3 and
PNU 1001.4.

l

Reads out PNU 1001.3
only.

1002

0 Start Set Number

68

Ċ

UINT8

RW

Ċ

0 ... 63

Standard position data sets

When positioning is started
via control word 1, the
selected data set is activated.

64 ... 67

Reserved

68

PROFIBUS position data set

1003

0 Motion Profile Type

0

Ċ

UNIT16

RW

Ċ

0

Jerk−limited ramp is deactivated

The acceleration/deceleration
time of the ramp cannot be
adjusted. When the ramp is
activated, the maximum time
(50 ms) is set automatically.

2

Jerk−limited ramp is activated

1050

0 Homing Method

1

Ċ

INT8

RW

Ċ

Homing to

Selection of the homing
method to be used.

1

the negative limit switch with zero
pulse evaluation

2

the positive limit switch with zero
pulse evaluation

17

the negative limit switch

18

the positive limit switch

33, 34

the zero pulse

35

the actual position (no movement)

−1

the negative end stop with zero pulse
evaluation

−2

the positive end stop with zero pulse
evaluation

−17

the negative end stop

−18

the positive end stop

Advertising