4 dynamic position data set, Dynamic position data set, Commissioning – Lenze 931K User Manual

Page 36

Advertising
background image

Commissioning

"Positioning" mode
Dynamic position data set

6

l

36

KHB 13.0004−EN 2.1

6.6.4

Dynamic position data set

If the application requires positioning with different settings and driving profiles, use
dynamic positioning via position data set 68:

ƒ

Selection of the driving profile via PROFIBUS.

ƒ

Changing between absolute and relative positioning via control word 1.

ƒ

Interruption of a running positioning task and approaching of a new target via a
start command.

"Settings" tab sheet

ƒ

Open the Parameters

W Positioning W Destination parameters... menu.

931e_34

ƒ

Settings required in SDC:
– Messages (0..63) box (see software manual for the controller)
– Start delay (0..15) box (see software manual for the controller)

ƒ

Control via PROFIBUS, control word 1:
– Bit 12 can be used to select between "relative" and "absolute" in the Positioning

(0..15) box.

– Bit 4 can be used to select "Ignore start command" in the Start during positioning

box and bit 13 to select "Wait for end of positioning run" or "Interrupt actual
positioning".

Advertising