4 digital outputs, 5 digital inputs, Digital outputs – Lenze 931K User Manual

Page 41: Digital inputs, Commissioning, Actual values digital outputs, States of the digital outputs, Reading the states of the digital inputs

Advertising
background image

Commissioning

Actual values

Digital outputs

6

l

41

KHB 13.0004−EN 2.1

6.7.4

Digital outputs

ƒ

States of the digital outputs.

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1140

0 Digital Outputs

0

Ċ

UINT32

RW

Ċ

Bit

Value

Triggering of the digital
outputs.
Important! Up to 10 ms may
pass between triggering and
switching of the output.
The state of an output can be
checked by reading out the
parameter.

0

00000001

h

Holding brake
(read only)

1 ... 15

Reserved

16

00010000

h

Ready for
operation (read
only)

17, 18

00060000

h

DOUT1, DOUT2
(read and write)

19 ... 32

Reserved

6.7.5

Digital inputs

ƒ

Reading the states of the digital inputs.

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1141

0 Digital Inputs

0

Ċ

UINT32

RO

Ċ

Bit

Value

Actual states of the digital
inputs.
The available digital inputs
depend on the
parameterisation of the
controller

0

00000001

h

Negative limit
switch (DIN7)

1

Reserved

2

00000002

h

Positive limit
switch (DIN7)

3

00000008

h

Controller enable
is missing (DIN9)

16 ... 25

03FF0000

h

DIN0 ... DIN9

26 ... 32

Reserved