3 motor data, Motor data, Parameter setting – Lenze 931K User Manual

Page 46: Global parameters motor data, Tlimitation in

Advertising
background image

Parameter setting

Global parameters
Motor data

7

l

46

KHB 13.0004−EN 2.1

7.2.3

Motor data

ƒ

Via PNU 1290.0 (iit Time Motor) you can set the duration of the maximum motor
current.
When the time has elapsed, the motor current is automatically limited to the
parameterised rated motor current.

ƒ

Via PNU 1290.1 (iit Ratio Motor) you can read out the actual utilisation of the I

2

t

limitation in [‰].

PNU

Name

Possible settings

Characteristics

Lenze

Selection

Description

1160

Temperature

Reading of different
temperatures.

0 Power stage

temperature

{1 °C}

Ċ

INT16

RO

Ċ

Reading of the current power
stage temperature.

1 Motor temperature

{1 °C}

Ċ

INT16

RO

Ċ

Reading of the current motor
temperature.

1290

Motor Data

Overload protection for the
motor connected.

0 iit Time Motor

2000

0

{1 ms}

10000

Ċ

UNIT16

RW

Ċ

Time for which the motor is
fed with the specified
maximum current.

l

When the time has
elapsed, the motor current
is automatically limited to
the rated current set.

1 iit Ratio Motor

{1 ‰}

Ċ

UNIT16

RO

Ċ

Reading−out of the actual
utilisation of the I

2

t

limitation.

Advertising