Troubleshooting and fault elimination, Table of error messages – Lenze 931K User Manual

Page 63

Advertising
background image

Troubleshooting

and fault elimination

Table of error messages

9

l

63

KHB 13.0004−EN 2.1

Error
number

Meaning

Activation

time

Response

Cause

Remedy

A

H W O

03

Motor overtemperature

< 100 ms

ю ю ю ¨ Motor overtemperature

l

Check if the motor cooling via the motor housing is
impeded as a result of deposits, etc. (if necessary, clean the
motor).

l

Are there any other sources of heat near the motor that
may additionally increase the ambient temperature and
thus lead to a reduced heat loss dissipation?

l

Check the controller settings, poor settings will lead to an
unnecessary heat generation.

l

Reduce the load torque of the motor.

l

Check the setting of the temperature sensor.

l

Check the resolver and encoder cable for an open circuit.

l

Check the resolver position adjustment.

04

Overtemperature/
undertemperature of the
power electronics

< 100 ms

ю ю −

Overtemperature/undertemperature of
controller

l

Check if the controller has been correctly mounted into the
control cabinet:
– Heatsink must have large−surface contact with the

housing of the control cabinet.

– If required, remove other sources of heat from the

vicinity of the controller.

l

Clean the ventilation slots of the controller.

l

Optimise the controller settings (poor settings will lead to
an unnecessary heat generation).

l

Carry out a resolver position adjustment.

l

Reduce the load torque of the motor.

05

SinCos supply error

< 5 ms

þ −

Resolver or SinCos encoder error, reliable
detection only possible after approx. ½
motor revolution

l

Check resolver plug connection.

l

Check resolver cable for open or short circuit.

l

Check pin assignment of resolver cable plug.

l

Correct encoder parameters.

06

SinCos−RS485 communication
error

< 5 ms

þ −

07

SinCos track signal error

< 5 ms

þ −

08

Resolver, track signal error or
carrier failure

< 5 ms

þ −

09

5V−electronic supply error

< 5 ms

þ −

Angle encoder/ Hall−effect sensor
defective.

Replace encoder.

Collapse of supply voltage due to a wiring
error on X2

Check the wiring.

l

Error on techno module X8.

l

Voltage supply failure.

Send the controller in for repair.

10

12V−electronic supply error

< 5 ms

þ −

Angle encoder or SinCos encoder defective. Replace encoder.

Collapse of supply voltage due to a wiring
error on X2

Check the wiring.

Voltage supply failure.

Electronic error on the controller. Send the controller in for
repair.