Fold−out page on the right), Connections and interfaces, Status displays – Lenze EVF9333 User Manual

Page 110

Advertising
background image

l

110

EDKVF9333V DE/EN/FR 7.1

EVF9330 ... EVF9333

0Fig. 0Tab. 0

(fold−out page on the right)

Position

Description

0

Controller

1

Fixing bracket for standard mounting

2

EMC shield sheet with fixing screws for shielded control cables

3

Cover with fixing screws

4

Shield clamp and strain relief for the motor cable

5

Strain relief for the PE motor cable and the feed cable for the motor temperature monitoring with PTC thermistor
or thermal contact (NC contact)

Connections and interfaces

Position

Description

L1, L2, L3, PE Mains connection

^ 159

+UG, −UG

DC supply

^ 159

U, V, W, PE

Motor connection

^ 159

T1, T2

Connection of PTC thermistor or thermal contact (NC contact) of the motor

^ 159

X1

AIF interface (automation interface)

Slot for communication module (e. g. XT EMZ9371BC keypad)

X3

Jumper for setting analog input signal at X6/1, X6/2

^ 205

X4

System bus (CAN) connection

^ 206

X5

Connection of digital inputs and outputs

^ 199

X6

Connection of analog inputs and outputs

^ 199

X8

Connection of incremental encoder with TTL level or SinCos encoder and KTY temperature sensor
of the motor

^ 207

X9

Connection of digital frequency input signal

^ 210

X10

Connection of digital frequency output signal

X11

Connection of K

SR

relay output for "safe standstill" (for variants V004 and V024 only)

^ 202

Status displays

Position

LED red

LED green

Operating status



Off

On

Controller is enabled

On

On

Mains is switched on and automatic start is inhibited

Off

Blinking slowly

Controller is inhibited

Off

On

Motor data identification is active

Blinking quickly

Off

Undervoltage or overvoltage

Blinking slowly

Off

Active fault

Advertising
This manual is related to the following products: