Technical data – Lenze EVF9333 User Manual

Page 133

Advertising
background image

Technical data

Operation with rated power (normal operation)

Rated data for 400 V mains voltage

3

l

133

EDKVF9333V DE/EN/FR 7.1

9300

Rated output current at switching frequency

Max. permissible output current at switching

frequency

1)

2/4 kHz

3)

8 kHz

8 kHz sin 8/2 kHz

2)

16 kHz

2/4 kHz

8 kHz

8 kHz sin 8/2 kHz

2)

16 kHz

Type

I

r

[A]

I

r

[A]

I

r

[A]

I

r

[A]

I

r

[A]

I

max

[A]

I

max

[A]

I

max

[A]

I

max

[A]

I

max

[A]

EVF9321−xV

1.5

1.5

1.5

1.5

1.1

2.2

2.2

2.2

2.2

1.6

EVF9322−xV

2.5

2.5

2.5

2.5

1.8

3.7

3.7

3.7

3.7

2.7

EVF9323−xV

3.9

3.9

3.9

3.9

2.9

5.8

5.8

5.8

5.8

4.3

EVF9324−xV

7.0

7.0

7.0

7.0

5.2

10.5

10.5

10.5

10.5

1.8

EVF9325−xV

13.0

13.0

13.0

13.0

9.7

19.5

19.5

19.5

19.5

14.5

EVF9326−xV

23.5

23.5

23.5

23.5

15.2

35.0

35.0

35.0

35.0

22.9

EVF9327−xV

32.0

32.0

29.0

32.0

21.0

48.0

48.0

43.0

48.0

31.0

EVF9328−xV

47.0

47.0

43.0

47.0

30.0

70.5

70.5

64.0

70.5

46.0

EVF9329−xV

59.0

59.0

47.0

59.0

35.0

89.0

89.0

70.0

89.0

53.0

EVF9330−xV

89.0

89.0

59.0

89.0

46.0

134

134

88.0

134

69.0

EVF9331−xV

110

110

76.0

110

52.0

165

165

114

165

165

EVF9332−xV

150

147

92.0

150

58.0

225

221

138

225

87.0

EVF9333−xV

180

147

100

180

63.0

270

221

150

270

94.0

Bold print = Lenze setting

1)

The currents apply to a periodic load change with an overcurrent time of maximally 1 minute and a base load time
of 2 minutes with maximally 75 % I

rated

2)

Power−optimised operation with automatic switching frequency reduction. When the max. permissible output
current is exceeded, the switching frequency is reduced to 2 kHz.

3)

Possible for some types in case of other operating conditions: Operation with increased rated output current at the
same load change (see chapter "Operation with increased rated power")

Advertising
This manual is related to the following products: