Operation with increased rated power, Rated data for 400 v mains voltage, Technical data – Lenze EVF9333 User Manual

Page 136: 4 operation with increased rated power

Advertising
background image

Technical data

Operation with increased rated power
Rated data for 400 V mains voltage

3

l

136

EDKVF9333V DE/EN/FR 7.1

3.4

Operation with increased rated power

)

Note!

ƒ

The operation with increased rated power is not UL−certified.

ƒ

Operation with increased rated power is only allowed:
– In the listed mains voltage range
– With the listed switching frequencies
– With the specified fuses, cable cross−sections and mains chokes or mains

filters

3.4.1

Rated data for 400 V mains voltage

Basis of the data

Voltage

Frequency

AC mains connection

[U

N

]

3/PE AC 320 V − 0 % ... 440 V + 0 %

45 Hz − 0 % ... 65 Hz + 0 %

DC−mains connection
(alternatively)

[U

DC

]

DC 450 V − 0 % ... 620 V + 0 %

˘

Output voltage

With mains choke

3 ~ 0 approx. 94 % V

rated

˘

9300

Mains current

1)

Typical motor power

Output power

Power loss

ASM

(4−pole)

2/4 kHz

2)

U, V, W

+U

G

, −U

G

3)

Type

I

r

[A]

P

rated

[kW]

P

rated

[hp]

S

rated

[kVA]

P

DC

[kW]

P

loss

[W]

EVF9321−xV

1.7

0.55

0.75

1.3

1.72

50

EVF9322−xV

2.8

1.1

1.5

2.1

0.35

65

EVF9323−xV

5.0

2.2

3.0

3.8

0

115

EVF9324−xV

8.8

4.0

5.0

6.5

1.0

165

EVF9325−xV

15.0

7.5

10.0

11.1

0

260

EVF9327−xV

39.0

22.0

30.0

29.8

3.2

640

EVF9328−xV

50.0

30.0

40.0

39.5

0

810

EVF9329−xV

60.0

37.0

50.0

46.4

0

950

EVF9330−xV

97.0

55.0

75.0

74.8

0

1350

EVF9331−xV

119

75.0

100

91.5

0

1470

EVF9332−xV

144

90.0

125

110

13.1

2100

EVF9333−xV

185

110.0

150

142

20.6

2400

1)

Mains currents at a switching frequency of 2/4 kHz

2)

Switching frequency of the inverter

3)

Power supplied by the DC bus when operating with power−adapted motor