Mounting with fixing brackets (standard), Mechanical installation, Dimensions – Lenze EVF9333 User Manual

Page 152: Mounting

Advertising
background image

Mechanical installation

Standard devices in the power range of 55 kW
Mounting with fixing brackets (standard)

4

l

152

EDKVF9333V DE/EN/FR 7.1

4.4.2

Mounting with fixing brackets (standard)

Mounting material required from the scope of supply:

Description

Use

Quantity

Fixing bracket

Drive controller fixing

4

Hexagon head cap screw M8 × 16 mm
(DIN 933)

Mounting of fixing bracket to the drive controller

4

Washer

Æ 8.4 mm (DIN 125)

For hexagon head cap screw

4

Spring washer

Æ 8 mm (DIN 127)

For hexagon head cap screw

4

Dimensions

a

c1

e

b

1

d

d

1

b

l

c

³ 50 mm

³ 50 mm

g

m

k

0

³ 100 mm

³ 100mm

9300vec175

Fig. 4−9

Standard mounting with fixing brackets 55 kW

0 Arrange drive controllers in a row with spacing to be able to remove eye bolts

9300 vector

Dimensions [mm]

Type

a

b

b1

c

c1

d

d1

e

1)

g

k

m

EVF9331−EV

340

672

591

28.5

283

615

38

285

11

28

18

1)

For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Mounting

ƒ

Attach the fixing brackets to the heatsink plate of the drive controller.

Advertising