Rated data for 480 v mains voltage, Technical data, 2 rated data for 480 v mains voltage – Lenze EVF9333 User Manual

Page 134

Advertising
background image

Technical data

Operation with rated power (normal operation)
Rated data for 480 V mains voltage

3

l

134

EDKVF9333V DE/EN/FR 7.1

3.3.2

Rated data for 480 V mains voltage

Basis of the data

Voltage

Frequency

AC mains connection

[U

N

]

3/PE AC 384 V − 0 % ... 528 V + 0 %

45 Hz − 0 % ... 65 Hz + 0 %

DC−mains connection
(alternatively)

[U

DC

]

DC 540 V − 0 % ... 740 V + 0 %

˘

Output voltage

With mains choke

3 ~ 0 approx. 94 % V

rated

˘

Without mains choke

3 ~ 0 ... U

N

˘

9300

Mains current

1)

Typical motor power

Output power

Power loss

With

Mains choke

Without

Mains choke

ASM

(4−pole)

2/4 kHz

2)

8 kHz

2)

U, V, W

U, V, W

+U

G

, −U

G

3)

Type

I

r

[A]

I

r

[A]

P

rated

[kW]

P

rated

[hp]

S

rated

[kVA]

S

rated

[kVA]

P

DC

[kW]

P

loss

[W]

EVF9321−xV

1.5

2.1

0.37

0.5

1.2

1.2

2.3

50

EVF9322−xV

2.5

3.5

0.75

1.0

2.1

2.1

0.9

65

EVF9323−xV

3.9

5.5

1.5

2.0

3.2

3.2

0

100

EVF9324−xV

7.0

˘

3.0

4.0

5.8

5.8

2.5

150

EVF9325−xV

12.0

16.8

5.5

7.5

10.8

10.8

0

210

EVF9326−xV

20.5

˘

11.0

15.0

18.5

18.5

0

390

EVF9327−xV

29.0

43.5

18.5

25.0

26.6

26.6

11.8

430

EVF9328−xV

42.0

˘

30.0

40.0

39.1

39.1

4.6

640

EVF9329−xV

55.0

˘

37.0

50.0

49.9

49.9

0

810

EVF9330−xV

80.0

˘

55.0

75.0

69.8

69.8

5.9

1100

EVF9331−xV

100

˘

75.0

100

91.4

91.4

0

1470

EVF9332−xV

135

˘

90.0

125

124

124

32.4

1960

EVF9333−xV

165

˘

110.0

150

158.2

149

47.1

2400

1)

Mains currents at a switching frequency of 8 kHz

2)

Switching frequency of the inverter

3)

Power supplied by the DC bus when operating with power−adapted motor

˘

Operation allowed only with mains choke or mains filter