Technical data

Operation with increased rated power

Rated data for 400 V mains voltage

3

l

137

EDKVF9333V DE/EN/FR 7.1

9300

Rated output current at switching frequency

Max. permissible output current at switching

frequency

1)

2/4 kHz

2/8 kHz

2)

2/4 kHz

2/8 kHz

2)

Type

I

r

[A]

I

r

[A]

I

max

[A]

I

max

[A]

EVF9321−xV

1.8

1.8

2.2

2.2

EVF9322−xV

3.0

3.0

3.7

3.7

EVF9323−xV

5.5

5.5

5.8

5.8

EVF9324−xV

9.2

9.2

10.5

10.5

EVF9325−xV

15.0

15.0

19.5

19.5

EVF9327−xV

43.0

43.0

48.0

48.0

EVF9328−xV

56.0

56.0

70.5

70.5

EVF9329−xV

66.0

66.0

89.0

89.0

EVF9330−xV

100

100

134

134

EVF9331−xV

135

135

165

165

EVF9332−xV

159

159

225

225

EVF9333−xV

205

205

270

270

Bold print = Lenze setting

1)

The currents apply to a periodic load change with an overcurrent time of maximally 1 minute and a base load time
of 2 minutes with maximally 75 % I

rated

2)

Power−optimised operation with automatic switching frequency reduction. During operation with increased rated
power, the switching frequency is reduced to 2 kHz.

Advertising