Electrical installation

Standard devices in the power range 0.37 ... 11 kW

Important notes

5

l

163

EDKVF9333V DE/EN/FR 7.1

5.4

Standard devices in the power range 0.37 ... 11 kW

5.4.1

Important notes

To gain access to the power connections, remove the covers:

ƒ

Release the cover for the mains connection with slight pressure on the front and pull
it off to the top.

ƒ

Release the cover for the motor connection with slight pressure on the front and pull
it off to the bottom.

Installation material required from the scope of supply:

Description

Use

Quantity

Shield connection support

Support of the shield sheets for the supply cable and
motor cable

2

Hexagon nut M5

Fastening of shield connection supports

4

Spring washer

Æ 5 mm (DIN 127)

2

Serrated lock washer

Æ 5.3 mm

(DIN 125)

2

Shield sheet

Shield connections for supply cables, motor cable

2

Screw and washer assembly
M4 × 10 mm (DIN 6900)

Fastening of shield sheets

4