Operation with rated power (normal operation), Rated data for 400 v mains voltage, Technical data – Lenze EVF9333 User Manual

Page 132: 3 operation with rated power (normal operation)

Advertising
background image

Technical data

Operation with rated power (normal operation)
Rated data for 400 V mains voltage

3

l

132

EDKVF9333V DE/EN/FR 7.1

3.3

Operation with rated power (normal operation)

)

Note!

The controllers EVF9324, EVF9326 and EVF9328 … EVF9333 may only be
operated with the prescribed mains chokes and mains filters.

3.3.1

Rated data for 400 V mains voltage

Basis of the data

Voltage

Frequency

AC mains connection

[V

rate

d

]

3/PE AC 320 V − 0 % ... 440 V + 0 %

45 Hz − 0 % ... 65 Hz + 0 %

DC−mains connection
(alternatively)

[U

DC

]

DC 450 V − 0 % ... 620 V + 0 %

˘

Output voltage

With mains choke

3 ~ 0 approx. 94 % V

rated

˘

Without mains choke

3 ~ 0 ... U

N

˘

9300

Mains current

1)

Typical motor power

Output power

Power loss

With

Mains choke

Without

Mains choke

ASM

(4−pole)

2/4 kHz

2)

8 kHz

2)

U, V, W

U, V, W

+U

G

, −U

G

3)

Type

I

r

[A]

I

r

[A]

P

rated

[kW]

P

rated

[hp]

S

rated

[kVA]

S

rated

[kVA]

P

DC

[kW]

P

loss

[W]

EVF9321−xV

1.5

2.1

0.37

0.5

1.0

1.0

1.9

50

EVF9322−xV

2.5

3.5

0.75

1.0

1.7

1.7

0.7

65

EVF9323−xV

3.9

5.5

1.5

2.0

2.7

2.7

0

100

EVF9324−xV

7.0

˘

3.0

4.0

4.8

4.8

2.0

150

EVF9325−xV

12.0

16.8

5.5

7.5

9.0

9.0

0

210

EVF9326−xV

20.5

˘

11.0

15.0

16.3

16.3

0

390

EVF9327−xV

29.0

43.5

15.0

20.0

22.2

22.2

10.2

430

EVF9328−xV

42.0

˘

22.0

30.0

32.6

32.6

4.0

640

EVF9329−xV

55.0

˘

30.0

40.0

41.6

41.6

0

810

EVF9330−xV

80.0

˘

45.0

60.0

61.7

61.7

5.1

1100

EVF9331−xV

100

˘

55.0

75.0

76.2

76.2

0

1470

EVF9332−xV

135

˘

75.0

100

103.9

103.9

28.1

1960

EVF9333−xV

165

˘

90.0

125

131.2

124.7

40.6

2400

1)

Mains currents at a switching frequency of 8 kHz

2)

Switching frequency of the inverter

3)

Power supplied by the DC bus when operating with power−adapted motor

˘

Operation allowed only with mains choke or mains filter

Advertising