Electrical installation – Lenze EVF9333 User Manual

Page 198

Advertising
background image

Electrical installation

Standard devices in the power range 75 ... 90 kW
Motor connection

5

l

198

EDKVF9333V DE/EN/FR 7.1

T1

T2

PE

U

V

W

2

3

4

0

M4 x 12: 2.5 Nm (22.1 lb-in)
M5 x 12: 3 Nm (26.5 lb-in)

U, V, W,
PE

M10
30 Nm
264 lb-in

1

a

}

+

PE

9300vec125

Fig. 5−24

Motor connection with KTY thermal sensor

0 PE stud

PE cable connection with ring cable lug

1 U, V, W

Motor cable connection
Check the correct polarity. Observe maximum length of the motor cable.
Max. connectable cable cross−section: 240 mm

2

with ring cable lug

2 Shield clamps

Place shields of motor cable with large surface on the shield sheet and fasten with shield
clamps and M5 × 12 mm screws

3 Cable ties

Strain relief of motor cable

Advertising
This manual is related to the following products: