Mounting with fixing brackets (standard), Mechanical installation, Dimensions – Lenze EVF9333 User Manual

Page 157: Mounting

Advertising
background image

Mechanical installation

Standard devices in the power range 75 ... 90 kW

Mounting with fixing brackets (standard)

4

l

157

EDKVF9333V DE/EN/FR 7.1

4.5.2

Mounting with fixing brackets (standard)

Mounting material required from the scope of supply:

Description

Use

Quantity

Fixing bracket

Drive controller fixing

4

Hexagon head cap screw M8 × 16 mm
(DIN 933)

For fixing bracket

8

Washer

Æ 8.4 mm (DIN 125)

For hexagon head cap screw

8

Spring washer

Æ 8 mm (DIN 127)

For hexagon head cap screw

8

Dimensions

a

c1

e

b1

d

d1

b

l

c

³ 50mm

³ 50mm

g

m

k

0

³ 100mm

³ 100mm

9300vec134

Fig. 4−15

Standard mounting with fixing brackets 75 ... 90 kW

0 Arrange drive controllers in a row with spacing to be able to remove eye bolts

9300 vector

Dimensions [mm]

Type

a

b

b1

c

c1

d

d1

e

1)

g

k

m

EVF9332−EV
EVF9333−EV

450

750

680

28.5

393

702

38

285

11

28

18

1)

For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Mounting

ƒ

Attach the fixing brackets to the heatsink plate of the drive controller.

Advertising
This manual is related to the following products: