9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 107

L
Firmware 1.37 - 09/2006
107
9400 HighLine | Parameter setting & configuration
Motor interface
System block "LS_MotorInterface"
MI_dnActualMotorTorque_n
DINT
Current motor torque
• 100 % ≡
• Display in
in [Nm]
Signal flow - motor interface (C 95)
MI_dnActualMotorSpeed_n
DINT
Current speed of the motor shaft in [%]
• 100 % ≡ Motor reference speed (
Signal flow - encoder evaluation (C 109)
MI_dnActualMotorSpeed_s
DINT
Current speed of the motor shaft in [rpm]
• Display under
Signal flow - encoder evaluation (C 109)
MI_dnActualMotorPos_p
DINT
Current position of the motor shaft in [increments]
• Display under
Signal flow - encoder evaluation (C 109)
MI_-
dnActualDCBusVoltage_n
DINT
Actual DC-bus voltage
• 100 % ≡ 1000 V
Signal flow - motor interface (C 95)
MI_dnThermalLoadDevice_n
DINT
Thermal device utilisation in [%]
• Current result of the Ixt calculation.
MI_dnThermalLoadMotor_n
DINT
Thermal motor utilisation in [%]
• Current result of the I
2
xt calculation.
Output
DIS code | Data type
Value/meaning