2 monitoring of the device utilisation, 3 parameter for status display, Monitoring of the device utilisation – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 43: C 43), 9400 highline | parameter setting & configuration

L
Firmware 1.37 - 09/2006
43
9400 HighLine | Parameter setting & configuration
Drive interface
Parameter setting
4.2.2
Monitoring of the device utilisation
the device utilisation (i x t) is displayed over the last 180 seconds in [%].
r
If the value displayed in
exceeds the warning threshold set in
, the fault
message "device utilisation Ixt > C00123" is output and the fault response set in
occurs (default setting: "Warning").
r
If the value displayed in
exceeds 100 %, the fault message "device utilisation
Ixt > 100 %" is output and the fault response "Fault" occurs.
– The fault can only be reset if the value displayed in
is < 95 % again.
4.2.3
Parameter for status display
Parameters
Information
Controller command status
Active application
Status word 1
Status word 2
Device state
Active function state
Highlighted in grey = display parameter