9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | Operating mode "Electronic gearbox"
312
Firmware 1.37 - 09/2006
L
12.2.5.4
Setpoint conditioning
[12-16] "Setpoint conditioning" function in the signal flow (schematic diagram)
This function is used for speed ratio between the master shaft and the machine axis.
r
Parameter setting: Tab All parameters Category Electronic gearbox
ConvertElShaftMotor
r
Configuration: Tab FB editor FB ConvertElShaftMotor
n
Master value with trimming
o
Actual value
M
v
Slave
Real master/
Virtual master
v
t
Dv
C03006 = 0
Parameters
Lenze setting
Value Unit
C03715
Operating mode
Unit coupling
C03717/1
Reference variable X
1.0000
C03717/2
Reference variable Y
1.0000