C01124, C01190, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 608

9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01124
608
Firmware 1.37 - 09/2006
L
C01124
C01190
Parameter | Name:
C01124 | Sync PLL increment
Data type: UNSIGNED_8
Index: 23451
d
= 5B9B
h
Selection list
(Lenze setting printed in bold)
1 10 ns
2 21 ns
3 31 ns
4 41 ns
5 52 ns
6 63 ns
7 73 ns
8 83 ns
9 94 ns
10 104 ns
11 115 ns
12 125 ns
13 135 ns
14 146 ns
15 156 ns
16 167 ns
17 174 ns
18 182 ns
19 190 ns
20 198 ns
21 206 ns
22 213 ns
23 221 ns
24 229 ns
25 237 ns
26 245 ns
27 252 ns
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C01190 | Motor thermal sensor
Data type: UNSIGNED_32
Index: 23385
d
= 5B59
h
Selection list
(Lenze setting printed in bold)
Information
0 KTY83-110
Lenze standard KTY83-110 (MDSKX, MCS06)
1 Spec. characteristic
Characteristic defined via
2 KTY83-110 + 2 x PTC
Lenze standard KTY83-110 + 2 x PTC 150°C (MCS09-
MCS19)
;
Read access ; Write access CINH PLC STOP No transfer COM ; MOT