C01121, C01122, C01123 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 607: 9400 highline | parameter setting & configuration

L
Firmware 1.37 - 09/2006
607
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01121
C01121
C01122
C01123
Parameter | Name:
C01121 | Sync cycle time
Data type: UNSIGNED_32
Index: 23454
d
= 5B9E
h
Setting range
(min. value | unit | max. value)
Lenze setting
250
μs
13000 1000 μs
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C01122 | Sync phase position
Data type: UNSIGNED_32
Index: 23453
d
= 5B9D
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
μs
64000 0 μs
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C01123 | Sync window
Data type: UNSIGNED_32
Index: 23452
d
= 5B9C
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
μs
1000 0 μs
;