4 speed setpoint conditioning, Speed setpoint conditioning (c 250), 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 250

9400 HighLine | Parameter setting & configuration
Standard TAs
TA "Actuator – speed" | Speed setpoint conditioning
250
Firmware 1.37 - 09/2006
L
11.2.4
Speed setpoint conditioning
[11-4] Speed setpoint conditioning (schematic diagram)
The speed setpoint is defined in the Lenze setting via the analog input 1 and take place in
both directions (bipolar) and accordingly the driven machine part moves forward or
backward.
r
Parameter setting: Tab Application parameter Dialog level Overview
Gain
Invert setpoint
Selection
LS_Speed...
M
Speed
setpoint
DI2
DI3
DI4
OUT
IN
Ramp generator
%
1
%
2
%
15
Fixed setpoints
Status
machine
(basic drive
functions)
Speed setpoint
AIN1
M
v
Parameters
Lenze setting
Value Unit
C03002
Setpoint gain
100.00 %
Setpoint inputs of the function
Signal configuration
Lenze setting
Setpoint input
(Multiplexer parameters)
AIn 1 Speed setpoint
C03000