4 system block "ls_analoginput, 9400 highline | parameter setting & configuration, I/o terminals analog inputs – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 119

L
Firmware 1.37 - 09/2006
119
9400 HighLine | Parameter setting & configuration
I/O terminals
Analog inputs
7.2.4
System block "LS_AnalogInput"
The system block LS_AnalogInput displays the analog inputs in the function block editor.
Output
Data type
Value/meaning
AIN1_dnIn_n
DINT
Analog input 1
• Scaling:
±2
30
≡ ±10 V for use as voltage input
±2
30
≡ ±20 mA for use as current input
AIN2_dnIn_n
DINT
Analog input 2
• Scaling: ±2
30
≡ ±10 V
AIN1_bCurrentError
BOOL
Status signal "Current input error"
• Only when analog input 1 is used as current input.
• Application: Cable-breakage monitoring of the 4 ...20 mA circuit.
TRUE |I
AIN1
| < 2 mA
A1+
A1-
A1-
A1R
A2+
A2-
AIN1_dnIn_n
AIN1_bCurrentError
AIN2_dnIn_n
X3
LS_AnalogInput
250
C02731/1
C02730/1
C02732/1
C02731/2
C02730/2
C02732/2
C02800/1
C02800/2