2 virtual clutch, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 310

9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | Operating mode "Electronic gearbox"
310
Firmware 1.37 - 09/2006
L
12.2.5.2
Virtual clutch
[12-14] Function "Virtual clutch" in the signal flow (schematic diagram)
r
Parameter setting: Tab Application parameter Dialog level Overview Electronic
gearbox Virtual clutch
r
Configuration: Tab FB editor FB ClutchElectricalShaft
n
Master value with stretch factor
o
Master value with clutch
M
v
Slave
Real master/
Virtual master
v
t
Dv
C03006 = 0
Parameters
Lenze setting
Value Unit
C03673
Master value with stretch factor
- Unit/t
C03021
Activate clutch
Deactivated
C03665/1
Clutch in ramp
1.000 s
C03665/2
Decoupling ramp
1.000 s
C03665/3
Stop ramp
1.000 s
C03668
Jerk limitation
1.000 s
C03674
Master value with clutch
- Unit/t
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
DigIn 4 Close clutch
C03058/12
FALSE Clutch - positive opening operation
C03058/13