9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 352

9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Synchronism with mark synchronisation" | "Synchronism" mode"
352
Firmware 1.37 - 09/2006
L
TP profile parameters
r
Parameter setting: Tab Application parameter Dialog level Overview Synchronism
TP profile parameter
r
Configuration: Tab FB editor FB MarkSynchronizationTool
TP interface
r
Parameter setting: Tab Application parameter Dialog level Overview Synchronism
TP interface
Parameters
Lenze setting
Value Unit
C03855
Positioning mode
0
C03856
Deactivation mode
0
C03858/1
Positive speed
1000.0000 Unit/t
C03858/2
Negative speed
1000.0000 Unit/t
C03861/1
Acceleration ramp
1.000 s
C03861/2
Deceleration ramp
1.000 s
C03861/3
Stop ramp
1.000 s
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
FALSE Activate tool TP correction
C03058/23
Parameters
Lenze setting
Value Unit
C02810/2
Signal delay TP2
0 μs
C03031
Edge evaluation of positive edge
TRUE
C03032
Edge evaluation of negative edge
FALSE