MacDon FD70 for Combine Operators User Manual

Page 142

Advertising
background image

SECTION 10. MAINTENANCE AND SERVICING

Form 169006

140

Revision D

10.5.2 LUBRICATION POINTS

(Cont’d)

NOTE: REEL BEARING LUBE INTERVALS - 500 HOURS OR ONCE PER SEASON - WHICHEVER OCCURS
FIRST.

REEL CENTER BEARING (1 PLC)

DOUBLE REEL ONLY

REEL SHAFT RH BEARING (1 PLC)

REEL SHAFT LH BEARING (1 PLC)

REEL DRIVE CHAIN (1 PLC)

DOUBLE REEL SHOWN -

SINGLE REEL SIMILAR

REEL UNIVERSAL (1 PLC)

U-JOINT HAS AN EXTENDED LUBRICATION CROSS AND BEARING
KIT. STOP GREASING WHEN GREASING BECOMES DIFFICULT OR
IF U-JOINT STOPS TAKING GREASE. OVERGREASING WILL
DAMAGE U-JOINT
. 6 - 8 PUMPS IS SUFFICIENT AT FIRST GREASE
(FACTORY). DECREASE GREASE INTERVAL AS U-JOINT WEARS
AND REQUIRES MORE THAN 6 PUMPS.

Advertising
This manual is related to the following products: