10.11.7 Sickle

Hold-Downs

Check daily that sickle hold-downs are set to
prevent sickle sections from lifting off guards, but
still permit sickle to slide without binding.

NOTE

Guards should be aligned prior to
adjusting hold-downs.

10.11.7.1

Pointed Guard Adjustment

a. To adjust the clearance between the hold-down

and sickle for typical pointed guards:

1. Turn the adjuster bolts (A). Using a feeler

gauge, clearance from hold-down to sickle
section should be 0.004 - 0.024 in.
(0.1 - 0.6 mm).

NOTE

For larger adjustments, it may be
necessary to loosen nuts (B), turn
adjuster bolt (A), then re-tighten nuts
(B).

b. To adjust clearance between hold-down and

sickle:

1. Torque nuts (C) to 35 ft·lbf (46 N·m).

2. Turn the adjuster bolts (D). Using a feeler

gauge, clearance from hold-down to sickle
section should be:
 0.004 - 0.016 in. (0.1 - 0.4 mm) at guide

tip, and

 0.004 - 0.040 in. (0.1 - 1.0 mm) at rear of

guide.

3. Torque nuts (C) to 53 ft·lbf (72 N·m).

c. After adjusting all hold-downs, run header at a

low engine speed, and listen for noise due to
insufficient clearance. Insufficient clearance will
also result in overheating of the sickle and
guards. Re-adjust as necessary.

10.11.7.2

Stub Guard Adjustment

To adjust the clearance between the hold-down
and sickle for all stub guards:

a. Torque nuts (E) to 35 ft·lbf (46 N·m).

b. Turn the adjuster bolts (F). Using a feeler gauge,

clearance from hold-down to sickle section should
be:
 0.004 - 0.016 in. (0.1 - 0.4 mm) at guide tip,

and

 0.004 - 0.040 in. (0.1 - 1.0 mm) at rear of

guide.

c. Torque nuts (E) to 53 ft·lbf (72 N·m).

0.004 - 0.024 in

(0.1 - 0.6 mm)

A

B

0.004 - 0.016 in

(0.1 - 0.4 mm)

0.004 - 0.040 in

(0.1 - 1.0 mm)

C

D

0.004 - 0.040 in

(0.1 - 1.0 mm)

0.004 - 0.016 in

(0.1 - 0.4 mm)

F

E

Advertising